FAQ

Questions, answered.

SSDs

Which SSDs is maxRAID designed for?

maxRAID is designed for data‑center‑class TLC SSDs rated at 1 drive write per day (DWPD). These drives are our baseline for calculating wear and capacity.

Which interfaces are supported?

Any SSD interface — SATA, SAS, NVMe — and fabric targets such as iSCSI and NVMe‑oF. Most customers choose local drives for the best value and performance.

Do high‑endurance SSDs help?

It depends on the kind. Some high‑endurance SSDs simply add over‑provisioning, which reduces maxRAID’s benefit. Others use higher‑grade flash, and deliver the full benefit of maxRAID.

Can I use QLC SSDs?

Yes. Data‑center QLC SSDs perform well with maxRAID. They have QLC limitations, but maxRAID mitigates most of the performance and wear issues — with far less wear, QLC may handle workloads that typically require TLC.

What about drives with a large indirection unit?

maxRAID suits them well. Some newer, larger SSDs map blocks larger than 4K. Because maxRAID writes large aligned blocks, the larger indirection unit doesn’t affect performance or wear.

Do consumer SSDs work?

Yes. Consumer SSDs often have higher read latency, lower endurance and inconsistent performance due to pSLC caching. maxRAID mitigates many of these issues — in some cases consumer SSDs can even outperform data‑center SSDs in a parity array.

RAID levels

Which RAID levels does maxRAID support?

Single SSD, RAID‑0, RAID‑1, RAID‑5 and RAID‑6 — plus 3‑ and 4‑drive parity for even greater protection.

Which level should I use?

RAID‑5 is the most common choice: space‑efficient, fast, and it writes less in total than RAID‑10. RAID‑6 is nearly as fast — modern x86_64 processors hide most of the parity overhead — and survives more than one concurrent drive failure.

Is RAID 6 faster than RAID 10 on SSDs?

With traditional RAID, usually not: every small write to RAID‑6 costs extra reads and writes for parity. maxRAID removes that penalty. On six NVMe SSDs with 70% reads, maxRAID‑6 measured 10.4 GB/s against 8.1 GB/s for RAID‑10, and it keeps data on four of the six drives instead of three.

Does RAID 5 wear out SSDs faster?

Yes, with traditional RAID‑5: each small write also rewrites parity, so the SSDs absorb far more writes. In an 8‑drive array, SSDs that would last 3 years under RAID‑10 wear out in about 1.7. maxRAID writes whole stripes at once, which removes that extra wear.

What about RAID‑10, 50 or 60?

With maxRAID they offer no additional protection, capacity or performance over RAID‑5 or RAID‑6, so we don’t recommend them.

Linux

Which distributions are supported?

maxRAID is a kernel module, so we support specific kernels: every x86_64 production kernel from Red Hat for RHEL 8 and 9, select Rocky Linux and AlmaLinux releases, and all server “‑generic” x86_64 kernels for Ubuntu LTS 22.04 and 24.04. Other distributions are added based on demand.

Can you support a custom kernel?

Yes. We work with OEMs and major cloud providers to include their custom kernels in our build set.

Block device

How full should I keep the array?

We recommend about 80%. Performance stays predictable as the array fills, and keeping some free space gives maxRAID room to work — for the best speed and the longest drive life.

Where can I use a maxRAID device?

Anywhere you use a block device. It works with file systems, LVM and partitions (most customers use LVM).

Can I put swap on maxRAID?

Yes. maxRAID is swap‑safe and supports swap files, partitions and logical volumes.

Does maxRAID support snapshots?

Not natively. Use LVM or a snapshot‑capable file system on top of maxRAID.

Does it support TRIM and discard?

Yes. Writing blocks of all zeros or all ones is also treated as a trim, so space is reclaimed even without discard support in the client or hypervisor.

Which block sizes are supported?

The device can present either 512‑byte or 4K blocks, and can be configured to issue only 4K I/O to SSDs that require it.

Can I export maxRAID over the network?

Yes. Export a maxRAID device — or portions of it via LVM — over iSCSI or NVMe‑oF. maxRAIDOne adds NFS, SMB and S3 with a web interface and API.

Proxmox VE

Can Proxmox do HA without Ceph?

Yes. Proxmox VE high availability needs storage every node can reach: a SAN over iSCSI or NVMe‑oF, an NFS server, or ZFS replication between nodes (asynchronous, so a failover can lose the most recent writes). maxRAIDOne, free with maxRAID and in beta, gives two or more servers shared, thin‑provisioned volumes with snapshots through its Proxmox VE plugin.

Trial

How does the free trial work?

The trial lasts 120 days from installation and supports arrays up to 100 TB. If you need more, contact us.

How do I know if maxRAID will help my data?

Run maxRAID Tools. The non‑destructive device scan measures how compressible your data is and how full your devices are.

Still have a question? Ask our engineers

See it on your own hardware.

Try maxRAID free for 120 days, on arrays up to 100 TB.