RAID‑10
10+ years
$0five‑year SSD cost
- SSDs you buy
- 0
- SSDs you replace
- 0
- Usable, with your data
- 0 TB
Software RAID,
redesigned for SSDs.
RAID was built for spinning disks. maxRAID was built for flash: RAID‑10 speed with the efficiency of RAID‑5 and RAID‑6, longer drive life and inline compression — all at once.
The old trade‑off
RAID‑10
Half of every drive you buy goes to mirroring. You pay for it, power it, cool it — and only half reaches your applications.
RAID‑5 / RAID‑6
Every small write turns into a read‑modify‑write. Performance collapses under random writes, and SSDs wear out years early.
maxRAID
Parity capacity with better‑than‑mirror speed, less wear and compression on top. One change in how data is written.
Performance
Parity RAID that is faster than mirroring in our tests.
The idea
maxRAID places a flash translation layer above the RAID layer. Writes are gathered, compressed and aligned, then committed as full stripes. The read‑modify‑write penalty is avoided.
Traditional parity RAID
One small write. Four I/Os.
Every random write becomes a read‑modify‑write. Throughput collapses and the parity drive is hammered.
maxRAID
Many small writes. One stripe.
Writes gather in memory, compressed and aligned
Parity is computed in memory. The stripe is written once, in full, with no reads. The SSDs only ever see sequential writes.
Efficiency
120 TB of usable storage on 15 TB SSDs. RAID‑10 mirrors everything, so it needs sixteen drives. maxRAID uses parity — and compresses what it can.3
RAID‑10
16
maxRAIDno compression
9
maxRAIDtypical data
7
Fewer drives. Even before compression.
With highly compressible data, as few as 5.
Fewer drives, smaller servers, less rack space. Savings start on day one.
Fewer drives to power, cool, monitor and replace — every year.
Choose 1 to N‑1 parity drives. Add protection without giving up speed.
Endurance
Traditional RAID‑5 writes every update twice — data and parity — so a workload that lasts three years on RAID‑10 can wear out RAID‑5 drives in under two. maxRAID writes less than RAID‑10 does.
No drive swaps. No maintenance windows.
How fast does RAID‑5 wear SSDs?
RAID‑5 life ≈ RAID‑0 life ÷ 2 × N ÷ (N − 1)
36 months on RAID‑0 becomes about 20.5 months in an 8‑drive RAID‑5 array.
Three questions. We’ll compare RAID‑10, traditional RAID and maxRAID: how long the drives last, and what they cost.
Over five years, maxRAID costs less in SSDs.
10 × 15.36 TB SSDs: 8 data + 2 parity · drive life5 and cost over five years, drives only
10+ years
$0five‑year SSD cost
10+ years
$0five‑year SSD cost
10+ years
$0five‑year SSD cost
Under the hood
Random writes become large, aligned sequential writes across every SSD.
A host‑side FTL that minimizes write amplification and keeps performance flat.
Blocks are compressed before they’re written. Often, write amplification drops below 1:1.
Blocks of all zeros or ones are discarded automatically — no client or hypervisor support needed.
From single to N‑1 parity, including 3‑ and 4‑drive protection, with minimal overhead.
QLC, TLC, MLC or SLC. SATA, SAS or NVMe. Even drives with large indirection units.
Specifications
maxRAID is a Linux kernel module that presents a standard block device — usable anywhere a block device is.
Try maxRAID free for 120 days, on arrays up to 100 TB.