RAID‑10
5+ years
$0five‑year SSD cost
- SSDs you buy
- 0
- SSDs you replace
- 0
- Usable, with your data
- 0 TB
Software RAID,
redesigned for SSDs.
RAID was built for spinning disks. maxRAID was built for flash: RAID‑10 speed with the efficiency of RAID‑5 and RAID‑6, longer drive life and inline compression — all at once.
Flash is fastest, and wears least, when it’s written in long, even stripes. maxRAID turns your applications’ scattered writes into exactly that, so you get more performance and longer SSD life from the drives you already have.
The old trade‑off
Mirroring · RAID‑10
Two full copies of everything: half of every drive you buy holds the second copy. You pay for it, power it, cool it — and only half reaches your applications.
Parity · RAID‑5 / RAID‑6
Parity stores recovery data instead of a second copy — but every small write means extra reads and rewrites (read‑modify‑write). Performance collapses under random writes, and SSDs wear out years early.
maxRAID
Parity capacity with better‑than‑mirror speed, less wear and compression on top. One change in how data is written.
Performance
Parity RAID that is faster than mirroring in our tests.
The idea
maxRAID places a flash translation layer (FTL) — the layer that decides how data is written to flash — above the RAID layer. Writes are gathered, compressed and aligned, then written as full stripes, so parity needs no extra reads or rewrites.
Traditional parity RAID
One small write. Four I/Os.
Every random write becomes a read‑modify‑write. Throughput collapses and the parity drive is hammered.
maxRAID
Many small writes. One stripe.
Writes gather in memory, compressed and aligned
Parity is computed in memory. The stripe is written once, in full, with no reads. The SSDs only ever see sequential writes.
Efficiency
120 TB of usable storage on 15 TB SSDs. RAID‑10 mirrors everything, so it needs sixteen drives. maxRAID uses parity — and compresses what it can.3
Mirroring
16
maxRAIDno compression
10
maxRAIDtypical data
8
Fewer drives. Even before compression.
With highly compressible data, as few as 6.
Fewer drives, smaller servers, less rack space. Savings start on day one.
Fewer drives to power, cool, monitor and replace — every year.
Choose 1 to N‑1 parity drives. Add protection without giving up speed.
Endurance
Traditional RAID‑5 writes every update twice — data and parity — so a workload that lasts three years on RAID‑10 can wear out RAID‑5 drives in under two. maxRAID writes less than RAID‑10 does.
No drive swaps. No maintenance windows.
How fast does RAID‑5 wear SSDs?
RAID‑5 life ≈ RAID‑0 life ÷ 2 × N ÷ (N − 1)
36 months on RAID‑0 becomes about 20.5 months in an 8‑drive RAID‑5 array.
Three questions. We’ll compare RAID‑10, traditional RAID and maxRAID: how long the drives last, and what they cost.
Over five years, maxRAID costs less in SSDs.
10 × 15.36 TB SSDs: 8 data + 2 parity · drive life5 and cost over five years, drives only
5+ years
$0five‑year SSD cost
5+ years
$0five‑year SSD cost
5+ years
$0five‑year SSD cost
Under the hood
Small, scattered writes become large, even writes across every SSD.
Flash must clean up old data as it goes (garbage collection). maxRAID does it within 0.5% of the theoretical best, so performance stays flat.
Blocks are compressed before they’re written. Often, write amplification drops below 1:1.
Blocks of all zeros or ones are released (trimmed) automatically — no client or hypervisor support needed.
From one parity drive up to all but one, including 3‑ and 4‑drive protection, with minimal overhead.
QLC, TLC, MLC or SLC. SATA, SAS or NVMe. Even drives with large indirection units.
Specifications
maxRAID is a Linux kernel module that presents a standard block device — usable anywhere a block device is.
Try maxRAID free for 120 days, on arrays up to 100 TB.