How maxRAID works

One idea.
A better RAID.

maxRAID is a flash translation layer that runs in the host, above the RAID layer. It changes the write stream before it ever reaches your SSDs. Speed, capacity, endurance and cost all follow.

Your applications: random writes maxRAID: linearizes, compresses, aligns Your SSDs: full‑stripe writes

The problem

RAID was built for hard drives.

Parity RAID updates data in place. On SSDs, every small write becomes extra reads and extra writes — and the SSD’s own controller adds more hidden work on top. Speed drops. Drives wear out.

Traditional parity RAID

One small write. Four I/Os.

  1. Read old data
  2. Read old parity
  3. Write new data
  4. Write new parity
DDDDP

Every random write becomes a read‑modify‑write. Throughput collapses and the parity drive is hammered.

maxRAID

Many small writes. One stripe.

Writes gather in memory, compressed and aligned

DDDDP

Parity is computed in memory. The stripe is written once, in full, with no reads. The SSDs only ever see sequential writes.

The solution

Six steps. Every write.

  1. 01

    Gather

    Incoming writes — random, small, from any application — are collected in memory instead of being sent straight to the drives.

  2. 02

    Compress

    Each block is compressed in line. Less data written means more free space, fewer SSDs and less wear.

  3. 03

    Linearize

    Blocks are laid out sequentially and aligned to the SSDs’ internal geometry, so the SSD controllers avoid unnecessary work.

  4. 04

    Commit

    Parity is calculated in memory and the stripe is written once, in full, across every drive. No reads. No extra rewrites (read‑modify‑write).

  5. 05

    Collect

    A host‑side garbage collector reclaims space with near‑theoretical efficiency — within 0.5% of the optimal model.

  6. 06

    Trim

    Blocks of all zeros or all ones consume no space. Trim and discard work everywhere, without client or hypervisor support.

Why above RAID

Flash management belongs
in the server.

Inside an SSD, the flash translation layer can only see one drive. Above RAID, it sees the whole array — so RAID only ever processes linear, full‑stripe writes.

AmplificationReadWrite
maxRAID‑5None1.15×
maxRAID‑6None1.33×
  • What this means: for each 1 GB you write, maxRAID‑5 writes 1.15 GB to the SSDs. RAID‑10 writes 2 GB, because it mirrors everything.
  • Longer SSD life: in our 120 TB model, maxRAID needs no SSD replacements in five years. Under the same workload, RAID‑5 wears its SSDs out in about 20 months.

Where it shines

Made for real workloads.

The advantages are largest where writes matter: moderate to heavy write loads — at least 0.3 drive writes per day — with some data compressibility.

Databases

Steady low latency under mixed reads and writes.

Virtualization

Dense VM hosts without paying for mirrored drives.

AI & analytics

Massive datasets, sustained throughput.

Cloud and hosting

Predictable performance for every customer.

See it on your own hardware.

Try maxRAID free for 120 days, on arrays up to 100 TB.