Beta Q4 2026
maxRAID Grid
All the speed.
None of the copies.
Resilient block storage that scales out across many servers, built for cloud providers and AI workloads. Many servers, one system. Add servers and keep growing — rebalancing is automatic.
Architecture
Logical arrays that span the grid.
Each logical array is a maxRAID array protected by parity spread across servers: K data and M parity drives, each on a different server. In the example above, ten servers with ten SSDs form ten 8+2 arrays.
Spares, standing by.
Add a spare drive in every server, a spare server, or both. One spare server can stand by for several grids. When something fails, rebuild starts at once — shortening the time arrays run degraded.
Redundancy from the grid itself.
Protection comes from parity across servers — without buying mirrored media.
No central bottleneck.
There is no central metadata server: each array runs independently and performs like a local array. The grid is managed with maxRAIDOne.
How it grows.
Start with a square.
Ten servers with ten SSDs each: ten 8+2 arrays. The number of SSDs per server is set here; any extras stand by as hot spares.
Add a whole grid.
The simplest way to grow: a second 10 × 10 grid is a separate cluster with its own 8+2 arrays, and doubles capacity and performance. Two 10 × 10 grids are better than one 20 × 10: each keeps its network traffic separate.
Or add servers one at a time.
Each server brings one more 8+2 array, and the data rebalances. With eleven servers, the grid hosts eleven arrays, and each server holds a drive in ten of them.
Performance
Add servers.
Add performance.
Each logical array performs like a local array. Clients stripe each volume across arrays — and with no central metadata server in the data path, every array you add contributes its full performance.
Logical arrays
Grow when you need to. Performance grows with you.
Operations per second (IOPS) add up the same way: up to 2 million per array — 20 million across the ten 8+2 arrays of ten servers with ten SSDs each.1
One system. Room for every tenant.
Local‑array speed.
No metadata bottleneck. Each array performs as if it were in the server.
Built for AI.
NVMe‑oF over TCP and RDMA, GPUDirect, and shareable multi‑mount volumes.
Grows with you.
From 50 TB to more than 10 PB. Use ultra‑large QLC SSDs to reach multi‑petabyte capacities.
Size your grid.
Move the sliders. Performance adds up array by array, until the network becomes the limit.
One 10 × 10 grid · 10 arrays, each with one drive in every server · spare server at right
- IOPS
- 20M
- Logical arrays
- 10 8+2 each
- Usable capacity
- 1.23 PB
- before compression
- Hardware
- 11 servers
- 100 NVMe drives in arrays, plus 1 spare server
- Survives
- 2 failed drives in every array
- Rebuild
- Starts at once
- onto the spare server
Illustrative estimates from design targets. For a real sizing of your workload, talk to an engineer.
Get a sizingEconomics
Less flash for every
usable terabyte.
Keeping three copies of every block leaves a third of your flash usable. An 8+2 parity array leaves 80% usable — and, like three copies, it survives any two drive failures.2
| One 10 × 10 grid · 10 TB SSDs | Ceph, three copies | maxRAID Grid |
|---|---|---|
| SSDs for 720 TB usable | 309 | 100 |
| Five‑year cost, all in | $1.54M | $710K |
| Usable from the same 100 SSDs | 233 TB | 720 TB |
209 fewer SSDs. About $833K less over five years.
With typical data that compresses by 30%, the same 100 SSDs hold about 940 TB.
Compression and thin provisioning.
In‑line, so every byte goes further.
Near‑theoretical wear.
Support for QLC and PLC SSDs with large indirection units.
Your hardware.
White‑box x86_64 servers, standard Ethernet and modest RAM.
Resilience
Servers fail.
Service doesn’t.
Failed SSDs are replaced automatically. Failed servers fail over to hot spares through virtual target IP addresses — automatically, and invisibly to applications.
Design targets1
Server + drive
Tolerates both server and drive failures.
< 30 s
Failover, from failure to service.
0
In‑flight data lost during failover.
Full speed
Writes stay at full speed in degraded mode.
At a glance
Built for cloud providers and AI workloads.
- Performance
- Up to 20 GB/s and 2M IOPS per logical array, read and write, when the network can carry it; volumes stripe across arrays
- Protection
- You choose the parity: 1, 2, 3 or more drives per array. Each array survives as many failed drives as it has parity drives — and losing a whole server costs each array only one. With 8+2 arrays, as in the 10 × 10 example, that means any two drives per array, or two whole servers. With a spare, rebuild starts at once.
- Scale
- 50 TB to 10+ PB
- Protocols
- NVMe‑oF (TCP, RDMA, GPUDirect) and iSCSI; shareable multi‑mount volumes for AI
- Multi‑tenancy
- Thousands of volumes per server; QoS by bandwidth or IOPS, burstable
- Data services
- Snapshots, backups, in‑line compression, thin provisioning
- Self‑healing
- Automatic SSD replacement; server failover to hot spares via virtual target IPs
- Integrations
- Kubernetes CSI driver, at general availability; Proxmox VE plugin planned
- Hardware
- White‑box x86_64 servers, standard Ethernet; any SSD: SATA, SAS or NVMe (TLC, QLC, PLC), NVMe for full performance
Data sheet (PDF) Brochure: More sellable flash (PDF) Cloud provider handout (PDF)
Scale without compromise.
maxRAID Grid enters beta in Q4 2026, with general availability targeted for Q1 2027.
- maxRAID Grid is pre‑release. Performance and resilience figures are design targets — up to 20 GB/s and 2 million IOPS per logical array, adding with each array a volume is striped across, provided the network can carry the traffic — and final figures will be published at general availability.
- All figures are modeled, not measured: one 10 × 10 grid — ten servers with ten 10 TB SSDs each, ten 8+2 arrays — 90% full; Ceph with three copies, 70% full. SSDs at $500 per raw TB; maxRAID Grid licence $120 per raw TB plus maintenance $18 per raw TB a year, five years counted; Ceph counted with no licence or support cost. Compression is modeled: data that compresses by 30% holds about 1.31 times as much.